1. Fresh Water Flake Ice Machine placement
(1) It should be placed in a place where air is circulated and cleaned around.
(2) It should not be placed in the open air, and should not be exposed to direct sunlight or rain. You can't get close to the heat source around.
(3) The environment in which the machine is used must not be lower than 5 ° C and not higher than 38 ° C.
(4) There should be enough space around the machine, especially the back can not be less than 250mm. So that the machine is cooling.
(5) Please adjust the anchor screw on the bottom of the machine to ensure the level of the machine is stable.
2, the installation of the water system
(1) Please connect the water source that meets the local drinking water standard.
(2) Attach a filter if necessary to increase the drinking standard of water.
(3) The water supply system must meet the following conditions:
a, the water temperature is at least 2 ° C, the maximum is not more than 38 ° C
b, the water pressure is at least 0.02Mpa, the highest is 0.8Mpa
3, the installation of the power supply
(1) The power supply must be the same as indicated on the machine nameplate.
(2) All lines must comply with national standards.
(3) It must be reliably grounded, and the grounding wire must meet electrical standards.
(4) The voltage fluctuation shall not exceed ±10% of the rated voltage.
Copyright © Guangzhou DAKA Refrigeration Equipment Co., Ltd. All Rights Reserved. | Sitemap | Powered by